Note that the delay time between switch D turning OFF and switch C turning ON corresponds to the right leg transition time. The control lC' s right leg delay feature (DELAY C-D) will be programmed for the maximum right leg transition time which will occur at high line and light load.
The longest transition time always corresponds to the converter's left leg transitions which are fully resonant. The maximum left leg transition time occurs when operating at the minimum ( critical) load current for ZVT operation, and at the highest input supply voltage. The shorter transition times always correspond to the converter's right leg transitions. The minimum right leg transition time occurs at full load with the lowest input supply voltage. Conversely, the maximum right leg transition coincides with light load, high line operation.
Залержка в правом (ведомом) устанавливается по максимуму, который следует из отношения - макс.питание+легкая нагрузка.
Далее, самые большие задержки на левом полумосте, т.е. ведущем. Самые короткие на правом, т.е. ведомом. Или что то я не понял? Вообще я менял и так и этак задержки, правда с ОС. Буду без нее сейчас мучать.