System Register (SYSR) Cannot be Read or Written Advisory DL_13
Revision(s) Affected: Revisions C, D, and F
Details: The System Register (SYSR) cannot be read or written without JTAG clock. SYSR does not control CLOCKOUT divisor when a JTAG connection to the debugger is not present. Writes to this register without JTAG fail to divide down clock out.
Assembler Notification: None
Workaround: None
E-mail: info@telesys.ru