У меня их 86 ERR :) на синтаксис он не показывает...т.к. я понимаю возник косяк при его внутреннем синтезе схемы. Вот описание ошибки:
----
CAUSE: The specified TRI or OPNDRN buffer primitive is connected to logic or a SOFT buffer, but not to a bidirectional (
BIDIR or BIDIRC) pin. A TRI buffer can only drive logic or a SOFT buffer if it is also connected to a bidirectional pin or if it is part of a tri-state bus. An OPNDRN buffer can only drive logic or a SOFT buffer if it is also connected to a bidirectional pin.
ACTION: Use a BIDIR or BIDIRC pin or remove the TRI or OPNDRN primitive.
>> Tri-state buffers must connect to an output or bidirectional pin. Internal nodes may not be tri-stated unless they are part of a tri-state bus.
---
...непонимаю в чём проблема ...синтаксис верный ...подскажите, что не так?